Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures.

Rt®-Alumina BOND/CFC Columns (fused silica PLOT)

 

*       Improved inertness for halogenated compounds.

*       Highly selective alumina-based column, separates most CFCs.

*       High retention and capacity for CFCs.

Product Name:

Rt-Alumina BOND/CFC

Temp. Limits:

to 200°C

Length:

30m

Internal Diameter:

0.53mm

df (µm):

10μm

 

1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored. 5. High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.

Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.

*       Improved inertness for halogenated compounds.

*       Highly selective alumina-based column, separates most CFCs.

*       High retention and capacity for CFCs.

The alumina adsorbent is ideal for retaining halogenated compounds, especially CFC (chlorinated flourocarbons, freons). It offers high selectivity, allowing a wide range of CFC isomers to be resolved at above ambient temperatures. The Rt®-Alumina BOND/CFC column is thoroughly deactivated to reduce the reactivity of alumina. Even though there is still some residual reactivity for some mono- or di-substituted halogenated hydrocarbons, the majority of these compounds can be accuray quantified from main stream processes or in impurity analyses.

 

 

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

您的留言已提交成功!我们将在第一时间回复您~
在线留言

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:
热线电话 在线询价
凯里市| 唐海县| 正蓝旗| 玛曲县| 留坝县| 德州市| 大理市| 莆田市| 乐至县| 邳州市| 龙江县| 台中县| 丽江市| 台东市| 龙门县| 洛宁县| 乐清市| 金平| 宿松县| 水富县| 广德县| 丘北县| 莆田市| 大宁县| 山东省| 平远县| 冷水江市| 平潭县| 奉化市| 台湾省| 徐州市| 宝鸡市| 固镇县| 工布江达县| 元谋县| 清水河县| 深泽县| 浮山县| 外汇| 泗洪县| 北票市|