亚洲精品综合日韩中文字幕网站_精品综合久久久久97_中文在线天堂网www_久久精品免费一区二区三区_91久久国产综合精品女同国语_久久资源总站在线国产成人

您好, 欢迎来到化工仪器网

| 注册| 产品展厅| 收藏该商铺

15601682291

products

目录:上海铂勒机电设备有限公司>>水质分析仪器>>其他水质分析仪及配件>> 2983700

2983700
  • 2983700
参考价 面议
具体成交价以合同协议为准
参考价 面议
具体成交价以合同协议为准
  • 品牌
  • 型号
  • 厂商性质 生产商
  • 所在地 上海市
属性

>

更新时间:2025-03-09 08:06:52浏览次数:817评价

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品
Accurate, Color-independent Measurement

Primary and active sludge with different structures and colors, dark digested sludge and light lime sludge make the highest demands on the precise measurement

Accurate, Color-independent Measurement

Primary and active sludge with different structures and colors, dark digested sludge and light lime sludge make the highest demands on the precise measurement of solids. Only SOLITAX sc solids probes with the patented dual scattered light method can satisfy these demands.

Self-cleaning Wiper Prevents Erroneous Values

The SOLITAX sc sensor's self-cleaning wiper prevents erroneous values and maintenance problems by preventing biological growth. Gas bubbles in the sample do not interfere with the measurement.

Excellent correlation to laboratory analysis

Comparisons between laboratory analysis and continuous suspended solids measurement using SOLITAX sc sensors show an exceptional correlation to mixed liquor, settled and thickened sludge. Online measurement not only saves time on manual analysis but also provides critical real time TSS measurements that can be used to operate the plant more efficiently.

Easy One-point Calibration

All SOLITAX sc probes are factory calibrated in conformity with DIN EN ISO 7027 for long-term calibration stability. Calibration is not necessary. If the probe is used to measure the solids content, a one-point calibration suffices. Multipoint calibration is available for nonlinear samples.

Improve overall efficiency of the plant

Any two SOLITAX sc sensors can be installed using one HACH sc200 Controller. Combinable with probes for O2, NO3, pH, etc. Any combination with other parameters helps improve process control.

What's in the box

Turbidity & Suspended Solids probe, controller, adapter, flange, user manual

Specifications

Accuracy:Turbidity up to 1000 NTU: 
without calibration < 5% of the measured value ±0.01 NTU
with calibration < 1% of the measured value ±0.01 NTU

Accuracy 2:Defined according to ISO/WD 13530.Turbidity Suspended Solids Less than of reading (depends on homogeneity of municipal activated sludge)

Cable Length:10 m (optional extension cables available)

Calibration:Turbidity Suspended Solids:Formazin or StablCal® Standard
Based on gravimetric TSS analysis with a correction factor procedure

Calibration Method:Turbidity: Formazin or STABLCAL Standard (at 800 NTU). 
Suspended Solids: Sample specific, based on gravimetric TSS analysis with a correction factor procedure.

Certifications:CE certified to EN 61326-1, EN 61326/A1, EN 61326/A2, EN 61010-1

Detection Limit:Turbidity
Suspended Solids

Diameter Sensor:(diameter x length)
Insertion sensor: 60 mm x(2.4 x)

Flow:Flow Velocity 3 m/s (9.8 ft./s) maximum

Length:(diameter x length)
Insertion sensor: 12.4 in ( 315 mm ) (12.4 in.)

Maintenance Interval:1 h/month

Material:Optics Carrier and Sleeve: stainless steel 1.4571; Wiper Arm: stainless steel 1.4581; Wiper Rubber: silicone rubber (standard) Optional: Viton (LZX578); Wiper Shaft: stainless steel 1.4571

Max. cable length Sensor-to-Controller:100

Measuring Principle:Infrared Duo scattered light technique for color-independent 
turbidity measurement Turbidity in accordance with 
DIN EN 27027 / TS equivalent DIN 38414

Measuring Range:Turbidity
Suspended Solids

Measuring Range TSS-Content:0.001 mg/L to

Measuring Range Turbidity:Suspended Solids 0.001 to 4000 FNU

Mounting:Through sidewall of a pipeline using a ball valve; minimum pipe size (4 in.) in carbon or stainless steel

Operating Temperature Range:0 to 40 °C

Pressure Limit:< 6 bar

Repeatability:< 3 %

Repeatability Turbidity:Defined according to ISO/WD 13530. Suspended Solids. Less than 1 % of reading

Response Time:Initial response in second

Response Time T90:1 to 300 s adjustable

Sample Temperature:>

Turbidity:Units of Measure Turbidity
Suspended Solids User selectable—NTU, FNU, or TE/F

Unit:Units of Measure
Turbidity
Suspended Solids: User selectable—g/L, mg/L, ppm, or % solids

Weight Sensor:2.4 kg

 

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

您的留言已提交成功!我们将在第一时间回复您~
在线留言

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:
热线电话 在线询价
视频| 衡阳市| 南雄市| 穆棱市| 峨山| 阿荣旗| 古田县| 大悟县| 九台市| 大关县| 伊宁市| 安西县| 汉沽区| 横山县| 丹江口市| 剑川县| 湛江市| 靖宇县| 社旗县| 莱州市| 健康| 固安县| 铜山县| 微山县| 镇平县| 台安县| 永靖县| 杂多县| 大余县| 黔西县| 马鞍山市| 西昌市| 四平市| 宁阳县| 滦平县| 开平市| 新化县| 同仁县| 余江县| 隆安县| 宜昌市|